SAFARI STROME

SR

NO

DTC

DESCRIPTION RESOLVE

PRIORITY

EFFECT ON VEHCLE

CAUSES

CHECK POINTS

CORRECTIVE ACTION

CEL

MIL

STATUS

88

P0692

Fan 1 Control

Circuit High.

M

1. AC is not functioning – AC Off.

2. Radiator fan will not run.

3. MIL is ON.

4. Reduced Torque active.

This DTC gets logged due

to Low speed fan (Top fan)

control is short circuit to

battery positive.

1. Check the fan control relay

connection.

2. Check electrical continuity.

3. Check ECU.

1. Check the fan control relay connection; Perform

necessary repairs if connection is faulty.

2. Check electrical continuity between ECU pin 66

to Relay connector as per circuit schematic;

Replace relay if problem persists. And perform

actuator test. Check whether the ecu pin 66 is short

circuit to battery. If so then rectify the wiring

harness connections.

3. Check ECU; Replace ECU; if problem persists.

4. Confirmatory check after rectification Perform

Actuator test for fan and visually check that fan is

operating. Also ensure radiator fan is rotating is

right direction.

Y

N

89

P0693

Fan 2 Control

Circuit Low.

M

1. AC is not functioning – AC Off.

2. Radiator fan will remain on continuously.

3. MIL is ON.

4. Reduced Torque active.

This DTC gets logged due

to (Bottom) High speed fan

is short circuited to ground.

1. Check the fan control relay

connection.

2. Check electrical continuity.

3. Check ECU.

1. Check the fan control relay connection; Perform

necessary repairs if connection is faulty.

2. Check electrical continuity between ECU pin 47

to Relay connector as per circuit schematic;

Replace relay if problem persists. And perform

actuator test check whether the ecu pin 47 is short

circuit to ground. If so then rectify he wiring harness

connections.

3. Check ECU; Replace ECU; if problem persists.

4. Confirmatory check after rectification Perform

Actuator test for fan and visually check that fan is

operating. Also ensure radiator fan is rotating is

right direction.

Y

N

90

P0694

Fan 2 Control

Circuit High.

M

1. AC is not functioning – AC Off.

2. Radiator fan will not run.

3. MIL is ON.

4. Reduced Torque active.

This DTC gets logged due

to Bottom fan is short

circuited to battery positive.

1. Check the fan control relay

connection.

2. Check electrical continuity.

3. Check ECU.

1. Check the fan control relay connection; Perform

necessary repairs if connection is faulty.

2. Check electrical continuity between ECU pin 47

to Relay connector as per circuit schematic;

Replace relay if problem persists. And perform

actuator test check whether the ecu pin 47 is short

circuit to battery. If so then rectify he wiring harness

connections.

3. Check ECU; Replace ECU; if problem persists.

4. Confirmatory check after rectification Perform

Actuator test for fan and visually checks that fan is

operating. Also ensure radiator fan is rotating is

right direction.

Y

N

91

P0698

Sensor

Reference

Voltage “C”

Circuit Low.

No critical effect.

2.5V sensor Supply 2Aux

fault – High.

1. Check the connection of

sensors supplied by

Reference voltage1 and

Reference voltage2.

2. Check sensor connections

for rust dirt etc.

3. Check ECU.

1. Follow Vext1 and Vext2 check /rectification

process.

2. Follow rectification process of concerned sensor

if faulty.

3. Replace ECU; if problem still persists.

N

N