TRANSAXLE
132
10. Tighten screw at the right torque 10 ± 1 Nm,
following the order shown in the image below.
11. Connect the connector of the wiring harness
on the ‘Transmission Control Unit’.
NOTE
Don’t reuse the AMT oil once it is drained
12. Fill the ‘Oil Tank’ with new ‘CS Speed’ oil, up
to the Max. Level @ no pressure in the
hydraulic circuit and restore it after the purge
procedure. Screw the ‘Oil Tank Cap’
at the
right torque 2 - 0.5 ± 1 Nm.