Automated Manual Transmission

25

New Actuators:

The guidelines of the procedure are illustrat-

ed below:

When?

After replacing KIT

After replacing clutch selection and/or en-

gagement solenoid valve

Why?

The objective of the routine is to force the

solenoid valve leakage to values which cor-

respond to those of new solenoid valves.

What tools are needed?

Diagnosis equipment

NOTES:

The procedure takes approximately 5 se-

conds. Power latch takes approximately 15

seconds. The procedure must be requested

with engine off and key on. To store the val-

ues in the ECU requires the key to be

extracted and the power latch to end.

Deleting statistical data

The guidelines of the procedure are illustrat-

ed below:

When?

Clutch unit replacement

Kit replacement

Replacing the gearbox

Button panel replacement

Steering wheel levers replacement

Replacing the pump

Replacing the accumulator only

Pump relay replacement

Resetting statistic data

Why?

Failure to carry out the procedure will not

affect system operation.

The following counters describe the history

of each single component, which is why,

when replacing a component referred to

above, it is necessary to zero or reset to de-

fault values the set of associated data. The

information in the following counters can

also identify the number of operations and

faulty conditions in which the system was

found when an error was validated.

What tools are needed?

Diagnosis equipment

TCU control unit replacement procedure

The guidelines of the procedure are illustrat-

ed below:

When?

This procedure must only be run after re-

placing the TCU.

Why?

Failure to carry out the procedure will not

affect system operation.

The following procedure allows the sys-

tem's history to be conserved (gearbox and

kit) transferring data from one TCU to an-

other.

This operation is possible if the services

necessary for its execution are not affect-

ed; i.e. if the TCU to be replaced does not

give the possibility of reading the data, the

procedure will not be able to be carried

out. As mentioned, in this case the system

operation is not affected.

If the TCU and any other component sub-

ject to the data set deletion procedure are

replaced at the same time, the data rec-

ords of the component to be replaced must

be deleted before copying the REWRITABLE