Background Image
Table of Contents Table of Contents
Previous Page  1325 / 1575 Next Page
Information
Show Menu
Previous Page 1325 / 1575 Next Page
Page Background

STORME 400NM

SR

NO

DTC

FTB

DESCRIPTION

CAUSES

EFFECT ON VEHICLE

CHECK

POINTS

CORRECTIVE ACTION

MIL

STATUS

CEL

215

P0616

11

Circuit Short to Ground

This fault gets logged if the starter

Control relay control pin of EMS ecu is

short circuited to Ground

1.

CE Lamp ON.

2.

Vehicle gets cranked in gear,

which may lead to jerk.

1.

Check whether the EMS ecu signal pin 207 is Short circuited to

ground due to wrong wiring harness connections, If so rectify

the wiring harness connections as per the schematic.

2.

Check the starter relay 1 & 2 wiring harness connections are as

per the schematic.

3.

Check whether the starter relay 1 / starter relay 2 contacts are

stuck open / Closed, if so then replace the starter relay 1 /

Starter relay 2.

4.

If problem still persists then replace the starter relay 2.

5.

If the problem still persists then replace starter relay 1.

6.

If still problem persists then replace the Water in Fuel Sensor.

7.

If still problem persists then replace the EMS ECU.

OFF

ON

216

P0617

12

Circuit short to battery

This fault gets logged if the starter

Control relay control pin of EMS ecu is

short circuited to battery

CE Lamp ON

1.

Check whether the EMS ecu signal pin 207 is short circuited to

battery, due to wrong wiring harness connections, If so rectify

the wiring harness connections as per the schematic.

2.

Check the starter relay 1 & 2 wiring harness connections are as

per the schematic.

3.

Check whether the starter relay 1 / starter relay 2 contacts are

stuck open / Closed, if so then replace the starter relay 1 /

Starter relay 2.

4.

If problem still persists then replace the starter relay 2.

5.

If the problem still persists then replace starter relay 1.

6.

After the fault rectification, crank the vehicle without pressing

clutch, vehicle should not start.

OFF

ON

217

P0615

2A

Signal Stuck In Range

This fault gets logged when the starter

relay contacts are stuck open

CE Lamp ON

1.

Check the starter relay 1 & 2 wiring harness connections are as

per the schematic.

2.

Check whether the starter relay 1 / starter relay 2 contacts are

stuck open / Closed, if so then replace the starter relay 1 /

Starter relay 2.

3.

If problem still persists then replace the starter relay 2.

4.

If the problem still persists then replace starter relay 1.

5.

After the fault rectification, crank the vehicle, vehicle should

start.

OFF

ON