1.5L REVOTORQ ENGINE
54
7. Step to be follow during de-aeration process
with coolant quantities.
Sr.
No.
Stage
Action
Coolant
Qty. (ml)
1
Initial filling
Fill the coolant
through
pressure cap
opening
3700
2
Cold fill –
Engine off
Coolant filled
until max level
of no loss tank
700
3
Pressure cap closed. Engine started &
maintained at 3000±100 rpm with AC
OFF.
4
2 Heat –Cool cycles done (i.e. Radiator
fan turns ‘ON’ & ‘OFF’ for two times).
5
Engine OFF. Leave engine to cool down
(preferably to ambient temperatures).
6
2nd filling
Fill the coolant
till neck of
pressure cap
200
Fill the coolant
till max level
400
Total Coolant
filled
5000