Background Image
Table of Contents Table of Contents
Previous Page  4101 / 4910 Next Page
Information
Show Menu
Previous Page 4101 / 4910 Next Page
Page Background

Q5/X451 FATC

DTC Troubleshooting Data

Version: 1.0

Date: 16-Oct-2018

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

Author: ERC

Page: 41 of 202

B1F2C-11:- Fresh Air/RECIRC Motor Drive Line- Circuit Short to Ground;

ISO Code

B1F2C- 11

Customer Symptom

No air selection control (manual or automatic)

Fault Effects (On Vehicle)

If polarity of motor lines is affected by fault, motor will

move to either end stop

Lamp Status (If Any)

Motor To be Disabled

Fault Detection Condition

Fresh/RECIRC Door Control Motor Drive Line - Circuit short

to ground

Normal Operating Condition

) With the Fresh/RECIRC motor drive line connected to the

harness and with Ignition ON, check the voltage between

blue connector pin no 7 & ground or 23 & ground. The

voltage range should be in between 0 to 14 V

Probable Trouble Area

Motor drive line is shorted to ground

Healing Condition

If there is a continuity between the Air Inlet door Motor

drive line and ground line correct the wiring harness (wiring

harness short to ground)

Component Details:

The recirculation/fresh air selector door actuator motor controls the position of the door which allows fresh air or

recirculation air, or a combination of the two, into the vehicle. The motor is mounted on the recirculation /fresh

air duct.

Preliminary Checks:

Switch On the IGN & perform the following check.

1)

Connect the Diagnostics tool & check the DTC fault code

2)

Read ECU parameter value

Target Position of Air-Inlet Door

Flap

and

AI Door flap Position (Internal Value)

for

actual and target position of Actuator