Q5/X451 FATC
DTC Troubleshooting Data
Version: 1.0
Date: 16-Oct-2018
Copyright ©
TATA MOTORS Ltd.
This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.
Author: ERC
Page: 33 of 202
B1F2E-12:- Air Distribution Motor Drive Line– Circuit short to Battery;
ISO Code
B1F2E- 12
Customer Symptom
No air distribution (mode) control (manual or automatic)
Fault Effects (On Vehicle)
If polarity of motor lines is affected by fault, motor will
move to either end stop
Lamp Status (If Any)
Motor To be Disabled
Fault Detection Condition
Mode Door Control Motor Drive Line - Circuit Short to
battery
Normal Operating Condition
With the Mode motor drive line connected to the harness
and with Ignition ON, check the voltage between blue
connector pin no 5 & ground or 21 & ground of the
Connector. The voltage range should be in between 0 to 14
V
Probable Trouble Area
Motor drive line is shorted to battery
Healing Condition
If there is a continuity between the Motor drive line and
battery line correct the wiring harness (wiring harness short
to battery)
Component Details:
The Mode Door Actuator controls the direction of airflow. It selects which way air flows through the different ducts.
Preliminary Checks:
Switch On the IGN & perform the following check.
1)
Connect the Diagnostics tool & check the DTC fault code
2)
Read ECU parameter value
Target Position of Mode Door Flap
and
Air Distribution Mode Door flap Position
(Internal Value)
for actual and target position of Actuator