Vehicle Platform: OSPREY

ECU Name: Hella Body Control Module (BCM) DTC

Troubleshooting Data

Version: 1.4

Date: 15 May 2018

Author: Body CoC

Page: 662 of 855

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

B1619 - 11: Internal Lock Switch - Circuit Short to Ground

ISO Code (DTC Code)

B1619 - 11

Customer Symptom

Customer is unable to open door.

Fault Effects (On Vehicle)

Door always locked.

Lamp Status (If Any)

Fault Detection Condition

This fault will be logged with IGN ON and internal

lock/unlock switch output short to ground.

Normal Operating Condition

This fault will be logged with IGN ON and internal

lock/unlock switch is pressed then door lock/unlock

operation happen alternately.

Probable Trouble Area

Lock/unlock switch output is Short to ground.

ECU fault.

Healing Condition

Run the input switch test routine and read the DTC. The

DTC B1619 – 11 shall not be logged.

Component Details:

BCM activate the door through internal lock/unlock Switch and output is STG for DTC B1619 - 11.

Preliminary Checks:

Check Battery Voltage (9V-16V)

Check ECU pins for oxidation, bending & damage.

Trouble Shooting:-