AIR CONDITIONING

40

11.17

FUNCTION AND INSPECTION OF A.C.

COMPONENTS:

Sr.

NO.

COMPONENT

FUNCTION

INSPECTION

1.

Fresh / Recirculation

actuator motor

Actuates the fresh /

recirculation flap as per

the user choice.

Remove the extreme left hand side grill cover

and by pressing the fresh/recirculation switch,

see the closing / opening of the flap. If it is not

working, no current should flow between the

terminals when the flap is at either of the ends.

2.

Blower Resistor

It operates the blower at

various speeds.

If the blower is not working at speed no 1,

2, and 3, and if it is working only at speed no

4, resistor has to be replaced with a new one.

3.

Anti-Freeze switch

It protects the A. C.

system from freezing

There should always be continuity, at both the

terminals. If there is no continuity, switch has to

be replaced

4.

Linear

Pressure

switch

Protects the A.C. system

from any consequential

damage.

Check the continuity. The ohm meter should

indicate zero reading. If, any resistance / open

circuit is observed, replace the switch with new

one

SR.

NO

.

COMPONENT

FUNCTION

INSPECTION

5.

VSV

(vacuum

solenoid valve)

Device for opening or

closing the vacuum path

to idle up actuator. The

V.S.V. opens or closes

according to the A/C

circuit, engine speed rises

a little higher than normal

idle speed

1. Remove vacuum hoses and electrical

connector from vsv

2. Check VSV for proper vacuum circuit

continuity.

3. Check VSV for short circuit signal from

multimeter should show open circuit between

each terminal and VSV body

6.

Magnetic clutch

Device for running the

compressor with when

the

air

conditioner

operation needed it is

controlled by A/C relay

and compressor relay

1. Disconnect electrical connector

2. Pulley should rotate freely with engine, supply

disconnected

3. Pulley should operate compressor is with

supply connected.

4. Check for noise