ELECTRICAL
261
Stop communication with Instrument Cluster
Turn Ignition Key Off
End
Verify,
Configured
parameters are
correct?
B
Yes
No
Disconnect “On Board Diagnostics” Cable
from Diagnostics connector
Read DTC codes from Instrument Cluster to ensure
that no faults identified on new Instrument Cluster
Read Configured data’s (Cluster Option Content and
Odometer
value) to ensure that Configured data’s are written correctly.
C
Refer Instrument Cluster
Diagnostics user manual
Refer Instrument Cluster
Diagnostics user manual