VERIFYWHETHERMALFUNCTIONS
ARE INCOMPRESSOROILAMOUNT
AND A/C COMPRESSOR OR
ELSEWHERE
When engine is racing, does high-
pressure value increase?
VERIFYWHETHERMALFUNCTIONS
ARE INCOMPRESSOROILAMOUNT
ORA/C COMPRESSOR
After compressor oil is replenished
each 10 ml, does high-pressure value
increase?
VERIFYWHETHERMALFUNCTION IS
IN EXPANSION VALVE OR
ELSEWHERE
Is only refrigerant low-pressure value
high?
VERIFY THATAIRMIX IS INSTALLED
SECURELYAND PROPERLY
Are heater unit’s air mix links, air mix
cranks and air mix rods securely and
properly installed?
VERIFY THAT EXPANSION VALVE
HEAT-SENSING TUBE WITHIN
COOLING UNIT IS POSITIONED
SECURELYAND CORRECTLY
Is expansion valve heat-sensing tube
within cooling unit securely installed in
proper position?
VERIFY THAT MALFUNCTION
SYMPTOMOCCURSAFTERREPAIR
Does cool air blow out? ( Are results of
refrigerant system performance test
okay?)
Return to step 3.
Go to next step
Troubleshooting completed. ( Explain to
customer that cause was insufficient
compressor oil.)
Replace A/C compressor. (Cause is
defectiveAC compressor)
Go to step 20.
Go to next step
Go to next step
Repair or install links, cranks and rods
securely in proper position.
Replace expansion valve, then go to next
step.( Since valve opens too much,
replacement is necessary.)
Install heat-sensing tube securely in
proper position, then go to next step
Troubleshooting completed.
Explain repairs to customer.
Recheck malfunction symptoms, then
repeat from step 1 if malfunction recurs.
When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while
doing the inspection to discover whether poor contact points are cause of any intermittent malfunctions. If there
is a problem, check to make sure connectors, terminals and wiring harness are connected correctly and
undamaged.