HVAC

11

12

13

14

• Are piping installation points onA/C

compressor free of gas leakage?

• Are piping installation on cooling unit

free of gas leakage?

• Perform gas leak inspection using

gas leak tester.

Are above items okay?

INSPECT EVAPORATOR PIPING

CONNECTIONS IN COOLING UNIT

FOR GAS LEAKAGE

Are piping connections for evaporator

in cooling unit free of gas leakage?

INSPECT EVAPORATOR PIPING

CONNECTIONS IN COOLING UNIT

FOR LOOSENESS

INSPECT PIPING CONNECTIONS

FOR LOOSENESS

Are piping connections loose?

VERIFYWHETHERMALFUNCTION IS

IN EXPANSION VALVE, AIR MIXAND

COMPRESSOR

OIL

OR

ELSEWHERE

Does refrigerant’s high-pressure value

hardly increase?

If the vane makes a noise, add 10 ml of

compressor oil to the A/C compressor.

Verify that the noise is no longer heard.

Adjust refrigerant to specified amounts.

If piping is damaged or cracked, replace

it.

If there is no damage, go to next step.

Tighten connections to specified torque.

If the vane makes a noise, add 10 ml of

compressor oil to the A/C compressor.

Verify that the noise is no longer heard.

Adjust refrigerant to specified amounts.

If the vane makes a noise, add 10 ml of

compressor oil to the A/C compressor.

Verify that the noise is no longer heard.

Replace O-ring on piping, adjust

refrigerant to specified amounts.

Tighten connections to specified torque.

If the vane makes a noise, add 10 ml of

compressor oil to the A/C compressor.

Verify that the noise is no longer heard.

Adjust refrigerant to specified amounts.

If the vane makes a noise, add 10 ml of

compressor oil to the A/C compressor.

Verify that the noise is no longer heard.

Adjust refrigerant to specified amounts.

Go to next step. ( Pressure hardly

increases.)

Go to step 17.

Yes

No

Yes

No

Yes

No

Yes

No

STEP INSPECTION