BRAKES
26
11.When the tool finishes bleeding the rear left wheel, pump the brake pedal until the fluid flowing out is free
of air bubbles; Close the bleed screw, Press “OK” to continue bleeding the Front Left wheel.
12.Continue to bleed the remaining wheels; the
diagnostic tool will follow the following
sequence.
! CAUTION
•
At all times during the bleeding process, it has
to be ensured that the fluid level in the
reservoir does not drop below minimum.
•
Allow a gap of 10 minutes before re-trying to
bleed the system using diagnostic tool. This is
needed to allow the solenoids to cool down.
13.After the bleeding sequence is completed
remove the bleed tube and place the dust cap
on the bleed screw.
14.Ensure that the bleed screw is tightened to the
recommended torque.
NOTE
After the bleeding is done check for any leaks in
the bleed screw by applying the brake pedal hard.