HVAC

34

TROUBLE SHOOTING

SR.NO. COMPLAINT

POSSIBLE CAUSE

REMEDY

1

Insufficient flow of cold

air

1. Evaporator clogged or frosted.

2. Air leaking from cooling unit or

air duct.

3. Air inlet blocked.

4. Blower motor faulty.

1. Check evaporator.

2. Repair as necessary.

3. Repair as necessary.

4. Replace blower motor.

2

Blower won't work even

when its switch is ON

1. Blower fuse blown.

2. Blower motor faulty.

3. Wiring or grounding faulty.

1. Replace fuse.

2. Replace motor.

3. Repair as necessary.

3

Incorrect temperature

output

1. Air ducts clogged.

2. Heater matrix leaking or

choked.

3. Heater hoses leaking or

choked.

4. Kinematics jammed.

1. Repair air ducts.

2. Replace heater matrix.

3. Replace hoses.

4. Repair/Replace kinemat-

ics.

4

Cold air comes out only

intermittently

1. Magnetic clutch slipping.

2. AC relay faulty.

3. Expansion valve faulty.

4. Wiring connection faulty.

5. Excessive moisture in the sys-

tem.

6. Faulty thermister cut-in and/or

cut-off setting.

1. Check magnetic clutch.

2. Replace faulty relay.

3. Check expansion valve.

4. Repair as necessary.

5. Evacuate and charge AC

system.

6. Replace thermister.