Background Image
Table of Contents Table of Contents
Previous Page  1345 / 1575 Next Page
Information
Show Menu
Previous Page 1345 / 1575 Next Page
Page Background

STORME 400NM

SR

NO

DTC

FTB

DESCRIPTION

CAUSES

EFFECT ON VEHICLE

CHECK

POINTS

CORRECTIVE ACTION

MIL

STATUS

CEL

246

P1675

12

CE lamp SC to VBatt fault

This DTC gets logged due to short

circuit to VBatt fault of the CE lamp

driver output of EMS ecu

CE lamp indication on Instrument

cluster will be OFF during bulb check

at Ignition ON and it will not turn ON

even when CE lamp related fault is

present.

1.

Check electrical continuity between EMS ECU pin 238 to

Dashboard cluster connector as per circuit schematic; follow

electrical continuity check procedure, Replace/rectify harness

if required.

2.

Check whether the EMS ecu pin 238 is SC to Battery supply.

3.

Check whether any other faults are present in EMS. If so,

rectify them by following their rectification procedure.

4.

If fault still persists then check whether EMS ecu is getting

Power supply and ground connections.

5.

Confirmatory check after rectification Check: Check whether the

CE lamp indication is ON during bulb check at Ignition ON and

going OFF after 3 sec of Ignition ON.

ON

OFF

247

P1675

13

CE lamp open circuit fault

This DTC gets logged due to open

circuit fault of the CE lamp driver output

of EMS ecu

CE lamp indication on Instrument

cluster will be OFF during bulb check

at Ignition ON and it will not turn ON

even when CE lamp related fault is

present.

1.

Check electrical continuity between EMS ECU pin 238 to

Dashboard cluster connector as per circuit schematic; follow

electrical continuity check procedure, Replace/rectify harness

if required.

2.

Check whether the EMS ecu pin 238 is SC to Battery supply /

Ground.

3.

Check whether any other faults are present in EMS. If so,

rectify them by following their rectification procedure.

4.

If fault still persists then check whether EMS ecu is getting

Power supply and ground connections.

5.

Confirmatory check after rectification Check: Check whether the

CE lamp indication is ON during bulb check at Ignition ON and

going OFF after 3 sec of Ignition ON.

ON

OFF

248

P0381

11

Glow Plug lamp short

circuit to ground fault

This DTC gets logged due to short

circuit to Ground fault of the glow plug

lamp driver output of EMS ecu

Start ability problem. (Torque

increase during start up if start fails).

1.

Check electrical continuity between EMS ECU pin 241 to

Dashboard cluster connector as per circuit schematic; follow

electrical continuity check procedure, Replace/rectify harness

if required.

2.

Check whether the EMS ecu pin 241 is SC to GND.

3.

Check whether any other glow plug related faults are present in

EMS. If so, rectify them by following their rectification

procedure.

4.

If fault still persists then check whether EMS ecu is getting

Power supply and ground connections.

5.

Confirmatory check after rectification Check: Check whether the

Glow Plug lamp indication is ON during bulb check at Ignition

ON and going OFF after 3 sec of Ignition ON.

OFF

OFF