SAFARI 400NM
SR
NO
DTC
FTB
DESCRIPTION
CAUSES
EFFECT ON VEHICLE
CHECK
POINTS
CORRECTIVE ACTION
MIL
STATUS
CEL
243
P226A
12
Water in Fuel Lamp Short
circiut to VBatt fault
This DTC gets logged due to short
circuit to VBatt fault of the water in fuel
lamp driver output of EMS ecu
1.
EGR is disabled. Reduced torque
mode activated.
2.
WIF lamp indication on Instrument
cluster will be OFF during bulb
check at Ignition ON and it will not
turn ON even water in fuel fault is
detected.
1.
Check electrical continuity between EMS ECU pin 250 to
Dashboard cluster connector as per circuit schematic; follow
electrical continuity check procedure, Replace/rectify harness
if required.
2.
Check whether the EMS ecu pin 250 is SC to Battery supply.
3.
Check whether any other faults are present in EMS. If so,
rectify them by following their rectification procedure.
4.
If fault still persists then check whether EMS ecu is getting
Power supply and ground connections.
5.
Confirmatory check after rectification Check: Check whether the
WIF lamp indication is ON during bulb check at Ignition ON
and going OFF after 3 sec of Ignition ON.
OFF
OFF
244
P226A
13
Water in Fuel Lamp Open
circuit fault
This DTC gets logged due to open
circuit fault of the water in fuel lamp
driver output of EMS ecu
1.
EGR is disabled. Reduced torque
mode activated.
2.
WIF lamp indication on Instrument
cluster will be OFF during bulb
check at Ignition ON and it will not
turn ON even water in fuel fault is
detected.
1.
Check electrical continuity between EMS ECU pin 250 to
Dashboard cluster connector as per circuit schematic; follow
electrical continuity check procedure, Replace/rectify harness
if required.
2.
Check whether the EMS ecu pin 250 is SC to Battery supply /
Ground.
3.
Check whether any other faults are present in EMS. If so,
rectify them by following their rectification procedure.
4.
If fault still persists then check whether EMS ecu is getting
Power supply and ground connections.
5.
Confirmatory check after rectification Check: Check whether the
WIF lamp indication is ON during bulb check at Ignition ON
and going OFF after 3 sec of Ignition ON.
OFF
OFF
245
P1675
11
CE lamp SC to Ground
fault
This DTC gets logged due to short
circuit to Ground fault of the CE lamp
driver output of EMS ecu
CE Lamp will be continuously ON
after Ignition ON.
1.
Check electrical continuity between EMS ECU pin 238 to
Dashboard cluster connector as per circuit schematic; follow
electrical continuity check procedure, Replace/rectify harness
if required.
2.
Check whether the EMS ecu pin 238 is SC to GND.
3.
Check whether any other faults are present in EMS. If so,
rectify them by following their rectification procedure.
4.
If fault still persists then check whether EMS ecu is getting
Power supply and ground connections.
5.
Confirmatory check after rectification Check: Check whether the
CE lamp indication is ON during bulb check at Ignition ON and
going OFF after 3 sec of Ignition ON.
ON
OFF




