STORME 400NM

SR

NO

DTC

FTB

DESCRIPTION

CAUSES

EFFECT ON VEHICLE

CHECK

POINTS

CORRECTIVE ACTION

MIL

STATUS

CEL

107

P0480

13

Circuit Open

This fault gets logged if the Fan 1 relay

drive pin of EMS ECU is open circuited

EMS ECU doesn't activate AC

compressor relay even though AC

request is activated by customer and

applies default ac torque

1.

Check 30A fuse connected to power supply and EMS power

relay is not blown off. Replace the fuse if found faulty.

2.

Check the fan 1 control relay connection; Perform necessary

repairs if connection is faulty.

3.

Check whether supply is available to relay contact 1 at ignition

on condition.

4.

Check electrical continuity between ECU to Fan 1 Relay

connector as per circuit schematic; Replace relay if problem

persists. And perform actuator test. Check ECU pins and

connector pins for damage/rust. In case of rust then clean

them and refit the connector.

5.

Replace main relay if its contacts are stuck open.

6.

Check ECU, Replace ECU; if problem persists.

7.

Confirmatory check after rectification~ Perform Actuator test for

fan and visually check that fan is operating also ensure fan 1

in rotating in right direction.

OFF

ON

108

P0481

00

No Subtype information

This fault is a grouping fault for all Fan 1

related faults: P0481-13, P0481-12,

P0481-11.

1.

As this fault is a grouping fault for the following faults: P0481-

13, P0481-12,P0481-11.

2.

Follow the rectification procedure of any of the above

mentioned faults with which this fault code is appearing for

resolving this fault.

OFF

OFF

109

P0481

11

Circuit Short To Ground

This fault gets logged if the Fan 2 relay

drive pin in EMS ECU is Short circuited

to Ground.~2. This fault will be logged

only if Ignition is ON at the instant of

fault detection by EMS ECU.

EMS ECU doesn't activate AC

compressor relay even though AC

request is activated by customer and

applies default ac torque~

1

Check 30A fuse connected to power supply and EMS power

relay is not blown off. Replace the fuse if found faulty.

2

Check the fan 2 control relay connection; Perform necessary

repairs if connection is faulty.

3

Check whether supply is available to relay contact 1 at ignition

on condition.

4

Check electrical continuity between ECU pin to Fan 2 Relay

connector as per circuit schematic; Replace relay if problem

persists. And perform actuator test. Check ECU pins and

connector pins for damage/rust. In case of rust then clean

them and refit the connector.

5

Check whether the EMS ECU fan 2 relay drive pin is short

circuited to ground, if so then rectify the wiring harness

connections according to circuit schematics.

6

Check ECU, Replace ECU; if problem persists.

7

Confirmatory check after rectification~ Perform Actuator test

for fan and visually check that fan is operating. also ensure

fan 2 is rotating in right direction.

OFF

ON