Background Image
Table of Contents Table of Contents
Previous Page  1282 / 1575 Next Page
Information
Show Menu
Previous Page 1282 / 1575 Next Page
Page Background

SAFARI 400NM

SR

NO

DTC

FTB

DESCRIPTION

CAUSES

EFFECT ON VEHICLE

CHECK

POINTS

CORRECTIVE ACTION

MIL

STATUS

CEL

105

P0480

11

Circuit Short To Ground

This fault gets logged if the Fan

1.

Relay drive pin in EMS ECU is Short

circuited to Ground.

2.

This fault will be logged only if Ignition

is ON at the instant of fault detection

by EMS ECU.

EMS ECU doesn't activate AC

compressor relay even though AC

request is activated by customer and

applies default ac torque~

1.

Check 30A fuse connected to power supply and EMS power

relay is not blown off. Replace the fuse if found faulty.

2.

Check the fan 1 control relay connection; Perform necessary

repairs if connection is faulty.

3.

Check whether supply is available to relay contact 1 at ignition

on condition.

4.

Check electrical continuity between ECU to Fan 1 Relay

connector as per circuit schematic; Replace relay if problem

persists. And perform actuator test. Check ECU pins and

connector pins for damage/rust. In case of rust then clean

them and refit the connector.

5.

Check whether the EMS ECU fan 1 relay drive pin is short

circuited to ground, if so then rectify the wiring harness

connections according to circuit schematics.

6.

Check ECU, Replace ECU; if problem persists.

7.

Confirmatory check after rectification Perform Actuator test for

fan and visually check that fan is operating also ensure fan 1

is rotating in right direction.

OFF

ON

106

P0480

12

Circuit Short To Battery.

This fault gets logged if the Fan

1.

Relay drive pin in EMS ECU is short

circuited to supply.

2.

This fault will be logged only if Ignition

is ON at the instant of fault detection

by EMS ECU.

EMS ECU doesn't activate AC

compressor relay even though AC

request is activated by customer and

applies default ac torque.

1.

Check 30A fuse connected to power supply and EMS power

relay is not blown off. Replace the fuse if found faulty.

2.

Check the fan 1 control relay connection; Perform necessary

repairs if connection is faulty.

3.

Check whether supply is available to relay contact 1 at ignition

on condition.

4.

Check electrical continuity between ECU to Fan 1 Relay

connector as per circuit schematic; Replace relay if problem

persists. And perform actuator test. Check ECU pins and

connector pins for damage/rust. In case of rust then clean

them and refit the connector.

5.

Check whether the EMS ECU fan 1 relay drive pin is short

circuited to battery, if so then rectify the wiring harness

connections according to circuit schematics.

6.

Replace main relay if its contacts are stuck closed.

7.

Check ECU, Replace ECU; if problem persists.

8.

Confirmatory check after rectification.

9.

Perform Actuator test for fan and visually check that fan is

operating also ensure fan 1 is rotating in right direction.

OFF

ON