TRANSMISSION 31 14. Push Transmission by hand against the flex plate. 15. Turn the crank pulley using a H19 wrench CLOCKWISE ONLY until the torque converter bolt hole is aligned with the flex plate bolt hole. 16. Install and Hand tighten 6 new screws. NOTE: Torque converter bolts are self-locking and must be replaced with new torque converter bolts every time the bolts are removed. 17. Tighten the screws to 6 to 6.5Kgfm. NOTE: Do not tighten before the 6 screws are in position. 18. Install the starter motor cover. 19. Control the starter motor dowel pin. If bend or damaged, replace it. 20. Install the starter motor. 21. Tighten the 3 starter motor screws to 3kgfm tightening torque.