HVAC 92 PIN OUT A Ground B Signal C Battery D Motor Negative E Motor Positive NOTE For removal refer On vehicle repairs in HVAC sec- tion. INSPECTION Check output from Control panel using Diagnostic Tool. TROUBLE SHOOTING Current drawn by the blower in speed 7 should be between 21 – 25A. SYMPTOMS CAUSES REMEDIES Blower running only in full speed. LPM faulty or not connected properly. Check LPM connector. Replace LPM if found faulty. Blower not running. LPM has shutdown due to over- heat. Check for any obstruction for blower rotation. Blower not responding. No output from Control panel. Check output from Control panel using Diagnostic Tool.