5. Disconnect the exhaust gas temperature sensor
wire harness connector (1).
6. Disconnect the upstream oxygen sensor wire
harness connector (1).
7. Disconnect the DPF temperature sensor wire
harness connector (1).
8. Loosen the fittings (1) and remove the pressure
sensor tube.
9. Loosen the clamp (2) and disconnect the
exhaust gas hose.
10. Remove the bolts (1) and the turbocharger heat
shield.
11. Loosen the nut (1) and reposition the DPF to
turbocharger clamp.