Background Image
Table of Contents Table of Contents
Previous Page  420 / 801 Next Page
Information
Show Menu
Previous Page 420 / 801 Next Page
Page Background

FATC

33

NOISE AND VIBRATION WHILE OPERATING A/C SYSTEM

TROUBLESHOOTING HINTS

Noise when compressor running at higher speed-Step 1-2

Vibration when compressor running at higher speed-Step 3

Hose or refrigerant line interference noise -Step 4.

STEP

INSPECTION

ACTION

1

Inspect oil quantity in the system. Check

oil leakage from any joint of Ac system

Yes

Top up correct grade and quantity of oil

No

Go to next step

2

Compressor mounting need to check.

Bracket mounting to be check.

Yes

Ensure proper tightening of all related fas-

tener

No

Replace AC compressor

3

Inspect AC compressor interface vibra-

tion.

Yes

Check damper condition. Bolt tightening

torque.

No

Go to next step

4

Inspect compressor Suction and Dis-

charge pipe. Mounting clamps and

rubber isolator.

Yes

Check compressor suction / discharge

pipe, Its rubber isolator

No

Go to next step

REFRIGERATION CYCLE TROUBLESHOOTING

Sr.

No.

OCCURANCE

POSSIBLE CAUSE

REMEDY

1

Insufficient refrigerant

Condition

Air conditioner does not cool effectively

Symptoms in refrigerant cycle

Pressure on both the high and low

pressure sides is low

Air around the air outlet is slightly cold

Cause

There is gas leakage in the refrigerating

cycle

Diagnosis

Insufficient refrigerant in the refrigerat-

ing cycle

Refrigerant leakage

Countermeasures

Locate the leakage and

repair

Recharge refrigerant to the

specified amount

Sr.

No.

OCCURANCE

POSSIBLE CAUSE

REMEDY