FATC

29

TROUBLE SHOOTING

STEP

INSPECTION

ACTION

1

Check working of AC compressor as

per logic (correct speed)

Yes

Go to next step

No

Check software

2

Inspect refrigerant system performance

Perform refrigerant system performance

test (Refer AC system performance test)

is operating normal?

Yes

Operation is normal. (Recheck malfunc-

tion symptoms)

No

Go to next step

3

Verify whether malfunction is in blower

unit intake and condenser or another.

Are refrigerant’s high-pressure and low

pressure values both high?

Yes

Go to next step

No

Go to step 6.

4

Inspect blower unit intake is blower unit

intake clogged

Yes

Remove obstruction. (If air does not reach

evaporator within cooling unit, heat ex-

change does not occur, refrigerant

pressure becomes high, and therefore,

removal of obstruction is necessary.)

No

Go to next step

5

Inspect condenser is it okay?

Yes

Adjust refrigerant to specified amount.

(Excessive amount of refrigerant.)

No

Replace condenser, or repair and clean

condenser fins.

6

Verify whether malfunction is in expan-

sion valve, receiver/drier and

refrigerant lines or elsewhere

Are refrigerant’s high-pressure and low-

pressure values low?

Yes

Go to next step

No

Go to step 14

7

Verify whether malfunction is in expan-

sion valve and receiver /drier or

elsewhere immediately after A/C com-

pressor operates, does refrigerant’s

high-pressure value momentarily rise to

correct value, then fall and stay below

it? (Is there negative pressure on low-

pressure side?

Yes

Go to next step

No

Go to step 10.