Based on the values the following conclusions can be inferred and further troubleshooting can be done.

Low Pressure

side in kg/cm2

( M Pa)

High Pressure side

in kg/cm2 ( M Pa)

Remarks

Symptoms

Possible reason

1.5-2.5 (0.15-

0.25)

14-16 (1.37-1.57)

System pressure is

normal

Normal cooling

AC system working

normal

0.5-1.0 (0.05-

0.1)

7-10 (0.69-0.98)

Pressure low

Insufficient cooling

1. Refrigerant quantity

too small. 2. Gas

leakage.

Vacuum

5-6 (0.5-0.6)

Refrigerant fails to

circulate

No cooling experi-

enced

Clogging of AC cycle.

Initially 1.5-2.5

(0.15

-0.25)

and later vacu-

um

Initially

14-16

(1.371.57)and later

7-10 (0.69-0.98

Moisture present in

system.

Initially works nor-

mally but later no

cooing experienced

Freezing of expansion

valve due to presence

of moisture.

4-6 (0.4-0.6)

7-10 (0.69-0.98)

Pressure on low

pressure side is

high and pressure

on high pressure

side is low.

No cooling.

Compressor defective

2.5- 3.5( 0.25 –

0.35)

20-25 ( 1.95-2.45)

System pressure is

high.

Only

Insufficient

cooling.

Excessive refrigerant

in the system causing

insufficient condenser

cooling

Insufficient cooling

with low pressure

piping will be hot.

Air has entered the

system.

In sufficient cooling

with frost or large

amount of dew on

low pressure piping

TXV valve faulty