Background Image
Table of Contents Table of Contents
Previous Page  4211 / 4910 Next Page
Information
Show Menu
Previous Page 4211 / 4910 Next Page
Page Background

Q5/X451 FATC

DTC Troubleshooting Data

Version: 1.0

Date: 16-Oct-2018

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

Author: ERC

Page: 151 of 202

B1F48-12:-

All HVAC & non-HVAC sensors Voltage reference pin- Circuit Short to battery

ISO Code

B1F48- 14

Customer Symptom

System is less responsive to user control and

environmental conditions

Fault Effects (On Vehicle)

Non HVAC sensor input out of range

Lamp Status (If Any)

Door flaps shall be timer controlled

Fault Detection Condition

If C2 - 14 of HVAC side connector to battery

Normal Operating Condition

FATC setting is updating properly as per user input.

Probable Trouble Area

HVAC connector wired wrong,

Sensor connector wired wrong,

harness wire shorted

Healing Condition

If there is a continuity between the C2-14 of HVAC side

connector and battery line correct the wiring harness

(wiring harness short to battery)

Component Details:

N/A

Preliminary Checks:

1.

Voltage at the battery terminals should be greater than 9V at the Ignition ON Condition.

2.

FATC power supply connector should have greater than 9V for normal functionality of FATC.

3.

Check battery cable and FATC connector terminals for damage.

4.

Check CCM for pin bend/damage.