HVAC
54
E. BLOWER
(FRONT HVAC UNIT)
1. Remove the HVAC cover located below glove
box.
2. Disconnect electrical connections.
3. Remove blower hose from HVAC casing.
4. Loosen and remove three mounting bolts and
separate the blower from the HVAC assembly.
FITMENT
For fitment follow reverse procedure of removal
F. BLOWER RESISTER
REMOVAL
1. Remove HVAC cover.
2. Disconnect electrical connection.
3. Loosen and remove screw of blower resister.
4. Take out blower resister unit
.
FITMENT
For fitment follow reverse procedure of removal.