FUEL SYSTEM

5

TROUBLE SHOOTING:

SR.NO

PROBLEM

CAUSE

SOLUTION

1

Leakage through Cylinder

valve threads

Over Tightening

In case over tightening the valve

threads will be damaged .Change the

valve with a new one and install it as

per given instruction

Teflon tape is not properly

wrapped

Unwrap the Teflon tape and again

wrap a new Teflon tape as per given

instruction .Always check the Cylinder

valve and Cylinder threads at the time

of installation of new valve.

2

In case of activation of PRD

devices

Due to high pressure or

temperature.

Change the Cylinder valve and do not

attempt to re-use the same valve.

3

If Cylinder valve is not

working

Current is not flowing in

solenoid coil.

Check all the connections with the

help of multimeter and if any

connection is loose then connect it.

Current is not flowing in

solenoid coil.

Change the solenoid coil as per

instruction given in maintenance

procedure.

4

If gas is not coming from

Cylinder.

Excess flow device is

activated due to the

pressure difference

1. Close the Cylinder valve and wait

for 15-20 Mins

2. Open the knob of cylinder valve

slowly.