FUEL SYSTEM

6

CYLINDER VALVE MAINTENANCE

PROCEDURE:

There is no preventive maintenance require for

Cylinder valve. However in case of damage of

solenoid coil / valve due to certain adverse

conditions, it may be necessary to replace the

solenoid coil / valve.

Solenoid coil / valve replacement procedure:

Disconnect the electrical connections.

Unscrew the fixing nut on top of the coil.

Remove the coil / valve as shown and change it

with the new one.

CAUTION

Always use only original valve / coil with

proper specification.

Apply lubricant Loxeal 85-21 on 2-3 threads

of fixing nut and remove excess lubricant.

Re-screw the fixing nut and tighten to a

torque of 0.7 Kg-m.

Re-connect electrical connection.