166
ENGINE 273 MPFI
SPECIFICATIONS
Radiator
Type
Aluminium
Number of Tubes
46
No. of Tube Rows
1
Leakage Testing Pressure
1.8 kgf/cm
2
Radiator Cap
Pressure at pressure valve opening
1.1 kgf/cm
2
Pressure at vacuum valve opening
0.05 kgf/cm
2
Coolant
Type
Antifreeze Agent (Ethylene Glycol) + Soft Water {Ratio 50 : 50}
Spec.
Class 2 / JIS K2234
Capacity
2 Litres w/o HVAC, 3.6 litres with HVAC
Thermostat
Operating Range
82 °C To 92 °C
Temp. at Start of opening
82 °C +/- 2 at 0.1 mm valve travel
Temp. at Full opening
92 °C +/- 2 at 8.0 mm valve travel
By pass port closed at before
87 °C
Leakage through main valve (including 150-250 litres/hr.
Seepage hole) at room temperature and
pressure of 1kg/cm²
Maximum leakage through by pass at
10 litres/minute
full open temperature or total
main flow Rate of 50 ± 5 litres/minute