ELECTRICAL
38
Sr
No DTC Code
DTC
Descriptio
n
Minimum Time for
Fault Setting /
Tester Visibility,
Assuming Fault
was created while
Ignition was OFF
Impact on customer Probable cause
Investigation/Rectificati
on/Repair action
10
B1911 15
Brake Fluid
Level
Warning
Indicator
Input -
circuit
short to
battery or
open
Post execution of
Service Self-Test
Routine (or) EOL
Self-Test Routine <=
20sec delay time.
Brake fluid TT will
always be turned
OFF till this DTC is
active.
Brake fluid input short or
open
Brake fluid input shorted
to battery positive or
Brake fluid input not
connected to IC or brake
fluid input wire cut.
11
B1911 11
Brake Fluid
Level
Warning
Indicator
Input -
circuit
short to
ground
Post execution of
Service Self-Test
Routine (or) EOL
Self-Test Routine <=
20sec delay time.
Brake fluid TT will
always be turned ON
till this DTC is active.
Brake fluid input short
Brake fluid input shorted
to battery negative
/Ground.
12
B190B 11
Ambient
Air
Temperatu
re Sensor
Input -
circuit
short to
ground
Post fault >=20 sec
delay.
No OAT input to
Cluster so no OAT
output from cluster to
TCU.
OAT sensor short
OAT sensor input
shorted to battery
negative or ground.
13
B190B 15
Ambient
Air
Temperatu
re Sensor
Input -
circuit
short to
Battery or
Open
Post fault >=20 sec
delay.
No OAT input to
Cluster so no OAT
output from cluster to
TCU.
OAT sensor short to Battery
or open
OAT sensor input
shorted to battery
positive or open.