ELECTRICAL
41
Sr
No DTC Code
DTC
Descriptio
n
Minimum Time for
Fault Setting /
Tester Visibility,
Assuming Fault
was created while
Ignition was OFF
Impact on customer Probable cause
Investigation/Rectificati
on/Repair action
21
B1914 12
Turn Left
Indicator
Input -
circuit
short to
battery
Post execution of
Service Self-Test
Routine (or) EOL
Self-Test Routine <=
20sec delay time.
Turn Left tell tale will
always be ON till this
DTC is active.
Turn left input short
Turn left input shorted to
battery positive.
22
B1915 11
Turn Right
Indicator
Input -
circuit
short to
ground
Post execution of
Service Self-Test
Routine (or) EOL
Self-Test Routine <=
20sec delay time.
Turn Right tell tale will
always be OFF till this
DTC is active.
Turn right input short
Turn right input shorted
to battery negative or
ground.
23
B1915 12
Turn Right
Indicator
Input -
circuit
short to
battery
Post execution of
Service Self-Test
Routine (or) EOL
Self-Test Routine <=
20sec delay time.
Turn Right tell tale will
always be ON till this
DTC is active.
Turn right input short
Turn right input shorted
to battery positive.
24
B1916 12
Hazard
Signal
Indicator
Input -
circuit
short to
battery
If Turn indicators R &
L are active more
than >2sec
Turn Left & Right tell
tale will always be ON
till this DTC is active.
Hazard input short
Hazard input shorted to
battery positive.
25
B1934 09
Set Switch
Button
Stucked
SET knob
continuous press >
20 sec
Customer will not
able to do the clock
settings, ETM mode,
Illumination setting
and one time odo
reset till this DTC is
active.
Set button damage
Check Button
mechanism