41

Sr

No DTC Code

DTC

Descriptio

n

Minimum Time for

Fault Setting /

Tester Visibility,

Assuming Fault

was created while

Ignition was OFF

Impact on customer Probable cause

Investigation/Rectificati

on/Repair action

21

B1914 12

Turn Left

Indicator

Input -

circuit

short to

battery

Post execution of

Service Self-Test

Routine (or) EOL

Self-Test Routine <=

20sec delay time.

Turn Left tell tale will

always be ON till this

DTC is active.

Turn left input short

Turn left input shorted to

battery positive.

22

B1915 11

Turn Right

Indicator

Input -

circuit

short to

ground

Post execution of

Service Self-Test

Routine (or) EOL

Self-Test Routine <=

20sec delay time.

Turn Right tell tale will

always be OFF till this

DTC is active.

Turn right input short

Turn right input shorted

to battery negative or

ground.

23

B1915 12

Turn Right

Indicator

Input -

circuit

short to

battery

Post execution of

Service Self-Test

Routine (or) EOL

Self-Test Routine <=

20sec delay time.

Turn Right tell tale will

always be ON till this

DTC is active.

Turn right input short

Turn right input shorted

to battery positive.

24

B1916 12

Hazard

Signal

Indicator

Input -

circuit

short to

battery

If Turn indicators R &

L are active more

than >2sec

Turn Left & Right tell

tale will always be ON

till this DTC is active.

Hazard input short

Hazard input shorted to

battery positive.

25

B1934 09

Set Switch

Button

Stucked

SET knob

continuous press >

20 sec

Customer will not

able to do the clock

settings, ETM mode,

Illumination setting

and one time odo

reset till this DTC is

active.

Set button damage

Check Button