Background Image
Table of Contents Table of Contents
Previous Page  1275 / 1575 Next Page
Information
Show Menu
Previous Page 1275 / 1575 Next Page
Page Background

STORME 400NM

SR

NO

DTC

FTB

DESCRIPTION

CAUSES

EFFECT ON VEHICLE

CHECK

POINTS

CORRECTIVE ACTION

MIL

STATUS

CEL

91

P0380

12

Circuit short to battery

This fault gets logged under the

following conditions:~

1.

Glow plug is not driven by ECU but

feedback is saying that glow plugs

are on or if the glow plug drive pin in

EMS ECU is short circuited to

Vbatt.~

Glow plug lamp is off.

1.

Check the 40A fuse of glow plug relay 1 and 2, replace if they

are blown off. Check the 30A fuse of EMS ECU main power

relay, replace if it is blown off.

2.

Check continuity between the glow plug drive pin A17 in EMS

ECU to the glow plugs 3 & 4 (as per circuit

schematics).Rectify wiring harness connections in case of

lack of continuity.

3.

Check whether the Glow feedback pin A17 of EMS ECU is

short circuited to Ground. If so, then rectify the wiring harness

connections according to circuit schematics. Check ECU pins

and connector pins for damage/rust. In case of rust then clean

them and refit the connector.

4.

Check whether the Glow plug drive pin of EMS ECU A85 is

short circuited to Battery/open circuited. If so, then rectify the

wiring harness connections according to circuit schematics.

5.

Check whether the resistance of glow plugs is according to

specifications, if not replace the glow plugs.

6.

Replace ECU if problem still persists.

OFF

ON

92

P0380

13

Circuit Open

This fault gets logged if the glow plug

drive pin in EMS ECU is open circuit

EMS ECU disables Xs ramp torque

function (Torque increase during start

up if start fails).

1.

Check continuity between the glow plug drive pin A85 in EMS

ECU to the glow plugs. Rectify wiring harness if any issues

like open circuits are found in the connection circuit of glow

plugs.

2.

Check electrical connections of 2 glow plug relays, if any issues

are found then rectify them according to the circuit

schematics. Check ECU pins and connector pins for

damage/rust. In case of rust then clean them and refit the

connector.

3.

Check glow plugs resistance and replace them resistance is not

according to design specifications (xx to xx ohms).

4.

Replace ECU if problem still persists.

OFF

ON

93

P0380

14

Circuit short to ground or

open

This fault gets logged under the

following conditions:~

1.

Glow plug is driven by ECU but

feedback is saying that glow plugs

are off.

EMS ECU disables Xs ramp torque

function (Torque increase during start

up if start fails).

1.

Check the 40A fuse of glow plug relay 1 and 2, replace if they

are blown off. Check the 30A fuse of EMS ECU main power

relay, replace if it is blown off.

2.

Check continuity between the glow plug drive pin A17 in EMS

ECU to the glow plugs 3 & 4 (as per circuit

schematics).Rectify wiring harness connections in case of

lack of continuity.

OFF

OFF