ZEST AND BOLT - page 1070

ELECTRICAL
104
FUEL VS RESISTANCE TABLE
FOR INSTRUMENT CLUSTER LOW END
SEGMENT
TANK
LEVEL(Lit)
RESISTANCE
(OHMS)
BAR ON
RESISTANCE(OHMS)
BAR OFF
RESISTANCE(OHMS)
LOW FUEL
WARING TT
TOLERANCE(±2 OHMS)
SHORT
CIRCUIT
5
BLINK @ 2Hz
10
42
8
10
16
LFW OFF
9
38.2
18
20
26
LFW OFF
8
34.4
28
30
35
LFW OFF
7
30.6
37
39
44
LFW OFF
6
26.8
46
48
54
LFW OFF
5
23
56
58
64
LFW OFF
4
19.3
66
68
74
LFW OFF
3
15.5
76
78
84
LFW OFF
2
11.8
86
88
95
LFW OFF
1
8
97
99
109
LFW ON with
2nd Segment
OFF
1 BAR
BLINK
4
111
IGN ON
LFW ON
OPEN
CIRCUIT
135
BLINK @ 2Hz
12.24.6 TEMPERATURE BAR GRAPH DETAILS
:
Temperature indication:
TEMPERATURE CALIBRATION TABLE
SEGMENT BAR ON TEMP. (ºC) BAR OFF TEMP. (ºC)
6seg
120
115
5seg
115
110
4seg
110
105
3seg
90
85
2seg
85
80
1seg (C)
-40
NA
Input type:
Can
Output:
LED bar graph in Instrument Cluster high end.
Absent in Instrument Cluster low end.
ECT TT (Duel Colour)
1...,1060,1061,1062,1063,1064,1065,1066,1067,1068,1069 1071,1072,1073,1074,1075,1076,1077,1078,1079,1080,...
Powered by FlippingBook