HARRIER SERVICE MANUAL PART -2

Q501 4 Cylinder MT Application DTC Troubleshooting Data Version: 0.1 Date: 21-Sep-2018 Prepared By: Mithi Prasad, Sarang Kulkarni, Manish Gupta Checked By: Yogesh Jadhav Approved By: Satish Kumar P Page: 1043 of 1052 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. 74 P268C-55 IMA classification injector 1 missed personalization NO 223 75 P268C-56 check of IMA quantisation type mismatch injector 1 NO 225 76 P268D-55 IMA classification injector 2 missed personalization NO 227 77 P268D-56 check of IMA quantisation type mismatch injector 2 NO 229 78 P268E-55 IMA classification injector 3 missed personalization NO 231 79 P268E-56 check of IMA quantisation type mismatch injector 3 NO 233 80 P268F-55 IMA classification injector 4 missed personalization NO 235 81 P268F-56 check of IMA quantisation type mismatch injector 4 NO 237 82 P0513-86 Incorrect Immobilizer Key: Bad ICU authentication NO 239 83 P0633-54 Immobilizer Key Not Programmed - ECM/PCM :MCU blank and free−starts exhausted NO 242 84 P1513-29 None plausible EEP values found NO 244 85 P3017-95 No valid key was detected NO 247 86 U1167-31 Frame VICM2 is absent NO 250 87 P1D4C-04 Injection system monitoring (system internal failures) NO 253 88 P1D45-49 Injection system monitoring (internal electronic failure) NO 255 89 P0611-92 Fuel injector control module performance NO 257 90 P242C-11 Inlet Diesel Particulate Filter exhaust gas temperature sensor (circuit short to ground) NO 259 91 P242D-15 Inlet Diesel Particulate Filter exhaust gas temperature sensor (circuit short to battery or open) NO 262 92 P0251-13 Metering Unit electrical failure (open circuit) NO 265 93 P0252-4B Metering Unit electrical failure (over temperature) NO 268 94 P0253-11 Metering Unit electrical failure (circuit short to ground) NO 271 95 P0031-11 HO2S Heater Control circuit low: Lambda probe upstream heater command signal low NO 274 96 P0032-12 HO2S Heater Control circuit high: Lambda probe upstream heater command signal high NO 278 97 P0053-1E Lambda sensor upstream heater diagnosis (circuit resistance out of range) NO 282 98 P112A-21 Lambda sensor upstream signal plausibility check (signal amplitude < minimum) NO 286 99 P112B-22 Lambda sensor upstream signal plausibility check (signal amplitude > maximum) NO 290 100 P2243-13 O2 sensor circuit: Lambda sensor wire diagnosis open load at pin IPE, sensor 1 bank 1 NO 294 101 P2626-13 O2 sensor circuit: Lambda sensor wire diagnosis open load at pin APE, sensor 1 bank 1 NO 298 102 P0131-11 O2 sensor circuit low voltage: Lambda sensor upstream wire diagnosis (circuit short to ground) NO 302

RkJQdWJsaXNoZXIy MTIwNTUz