HVAC

52

x. CONDENSER

1. Remove the radiator (Refer Radiator removal

process).

2. Loosen and remove the 4 condenser mounting

bolts on the radiator and separate out the con-

denser.

! CAUTION

Never leave the condenser lines open immediately

cover them with caps, otherwise the desiccant

which is in-built in the condenser may absorb the

moisture from surrounding air and get contaminat-

ed.

FITMENT

For fitment follow the reverse procedure of removal

.