Q5/X451 FATC

DTC Troubleshooting Data

Version: 1.0

Date: 16-Oct-2018

Copyright ©

TATA MOTORS Ltd.

This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author.

Author: ERC

Page: 53 of 202

B1F2F-12:- Blower Motor Drive Signal - Circuit Short to battery;

ISO Code

B1F2F - 12

Customer Symptom

Blower noise and annoyance

Fault Effects (On Vehicle)

Blower will be Off. Hence no heating or cooling will be

achieved

Lamp Status (If Any)

AC will be switched Off

Blower will be turned OFF

Fault Detection Condition

Blower Control Circuit Motor line- Circuit short to Battery

Normal Operating Condition

With the Blower control circuit connected to the harness

and with Ignition ON, check the voltage between pin no 24

of blue connector & ground of the Connector. The voltage

range should be in between 1.73 to 8.71 V.

Probable Trouble Area

Drive line is short circuited to battery

Healing Condition

If there is a continuity between the Blower control circuit

& battery line correct the wiring harness (wiring harness

short to battery)

Component Details:

The blower is used for moving air from either an outside source--referred to as vented air--or from cabin air past the

heater core or air conditioning evaporator. In doing so, it causes a heat transfer either to the inside of the car or from

the inside to the outside.

Preliminary Checks:

Switch On the IGN & perform the following check.

1)

Connect the Diagnostics tool & check the DTC fault code

2)

Read ECU parameter value

Blower Speed Output (Internal Value)

for Blower speed with the diagnostic tool