AIR CONDITIONING

2

11.2 TECHNICAL SPECIFICATIONS:

IMPORTANT SPECIFICATION

Make

Model Applicability

Refrigerant

Refrigerant charge Quantity

Compressor Lube oil used

Compressor oil (total quantity)

Lubrication Oil to be topped up in the system in

case of replacing any of the following aggregates:

a.

Receiver Drier

b.

Condenser

c.

Evaporator

d.

All Pipes

System Pressure: Car in stationary condition with

engine speed at 1500 rpm.

Discharge Pressure

Suction Pressure

High - Low safety pressure switch

Medium pressure switch

HVAC SYSTEM

BEHR / SUBROS

HVAC

R-134a

1. 500 ± 20 gm (BEHR QUADRAJET)

2. 500 ± 20 gm (BEHR REVOTRON)

3. 500 ± 20 gm (SUBROS QUADRAJET)

4. 500 ± 20 gm (SUBROS REVOTRON)

FD 46XG (PAG) EQV ND - 8

1. 100 ± 15 cc (BEHR QUADRAJET)

2. 100 ± 15 cc (BEHR REVOTRON)

3. 100 ± 15 cc (SUBROS QUADRAJET)

4. 100 ± 15 cc (SUBROS REVOTRON)

20 ml

20 ml

20 ml.

10 ml. each

15 kg / cm2 to 28 kg / cm2

1.5 kg / cm2 to 3.5 kg / cm2

2 kg / cm2 to 32 kg / cm2

Cut off at 15.5 kg / cm2 Cut in at 20.5 kg / cm2

for two speed condenser fan