HVAC

42

REFRIGERATION CYCLE TROUBLESHOOTING

Sr.

No.

Possible Cause

Remedy

1

Insufficient refrigerant

Condition

x

Air conditioner does not cool effective-

ly

Symptoms in refrigerant cycle

x

Pressure on both the high and low

pressure sides is low

x

Air around the air outlet is slightly cold

Cause

x

There is gas leakage in the refrigerat-

ing cycle

Diagnosis

x

Insufficient refrigerant in the refrigerat-

ing cycle

x

Refrigerant leakage

Countermeasures

x

Locate the leakage and

repair

x

Recharge refrigerant to the

specified amount

2

Excessive refrigerant

or insufficient conden-

ser cooling

.

Condition

x

Air conditioner does not cool effective-

ly

Symptoms in refrigerant cycle

x

Pressure on both the high and low

pressure sides is high.

Cause

x

Refrigerant is overcharge in the re-

frigerating cycle causing poor cooling

performance

x

Condenser cooling performance is

poor.

Diagnosis

x

Excessive refrigerant in the refrigerat-

ing cycle.

x

Overcharged refrigerant.

Poor condenser cooling performance.

Countermeasures

x

Clean the condenser.

x

Tighten the fan belt to the

correct tension.

x

Above are all normal

check the refrigerant.