HVAC

36

Step

Inspection

Action

7

Verify whether malfunction is in

expansion valve and receiver

/drier or elsewhere immediately

after A/C compressor operates,

D

RHV UHIULJHUDQW¶V KLJK

-pressure

value momentarily rise to correct

value, then fall and stay below it?

(Is there negative pressure on

low-pressure side?)

Yes

Go to next step

No

Go to step 10.

8

Verify whether malfunction is in

expansion valve or receiver/drier.

Turn A/C switch off and air condi-

tioner stop for 10 minutes start

engine turn both A/C switch and

fan switch on. Does malfunction

occur after compressor turn on?

Yes

Go to next step

No

Replace condenser and vacuum refrigerant line

more than 30 minutes by vacuum pump, and

refrigerant to specified level.

(Since water has

intermixed in receiver/drier and it is saturated,

replacement is necessary.)

9

Verify that expansion valve heat-

sensing tube within cooling unit is

positioned securely and correctly

is expansion valve heat-sensing

tube within cooling unit securely

installed in proper position?

Yes

Replace expansion valve.

(Since valve closes

too much replacement is necessary.)

No

Install heat-sensing tube securely in proper po-

sition.

10

Inspect refrigerant lines

x

Is piping free of damage and

cracks?

x

Are piping connections free of

oil grime? (visual inspection)

x

Are piping installation points on

a/c compressor free of gas

leakage?

x

Are piping installation on cool-

ing unit free of gas leakage?

x

Perform gas leak inspection

using gas leak tester.

Are above items okay?

Yes

Go to next step

No

If piping or an A/C component is damaged or

cracked, replace it.

11

Inspect evaporator piping connec-

tions in cooling unit for gas

leakage Are piping connections

for evaporator in cooling unit free

of gas leakage?

Yes

If the vane makes a noise, add 10ml of com-

pressor oil to the A/C compressor. Verify that

the noise is no longer heard. Adjust refrigerant

to specified amounts.

No

If piping is damaged or cracked, replace it.

If there is no damage, go to next step.

12

Inspect evaporator piping connec-

tions in cooling unit for looseness

Yes

Tighten connections to specified torque.

If the vane makes a noise, add 10 ml of com-

pressor oil to the A/C compressor.

Verify that the noise is no longer heard. Adjust

refrigerant to specified amounts.

No

If the vane makes a noise, add 10 ml of com-

pressor oil to the A/C compressor.

Verify that the noise is no longer heard. Re-

place O-ring on piping, adjust refrigerant to

specified amounts.