486 PL ENGINE

P

UNIQUE FEATURES OF 486 PL ENGINE

l

Electronically controlled sequential fuel

injection engine :

Fuel Injection and Ignition are controlled through

Intelligent microprocessor programmed to give

best performance under all operating conditions.

486 PL EMS-ECU is located on LH side firewall

below glow box assembly. Fig 1

l

Distributor-less ignition system :

Ignition timing controlled through mapped data

of ECU and hence no tuning / adjustment /

required. Maintenance free.

l

Better starting under all operating conditions :

No need to give choke for cold start. No hot

start problem.

l

Four valves per cylinder :

Technology for improved engine breathing and

performance.

l

Hydraulic tappets :

Zero tappet clearance at all times and no tappet

adjustment and maintenance required (Self

adjusting tappets). Maintenance free.

l

Canister purging :

Through ECU for good startability and smooth

running under all operating conditions.

l

Fuel cut off

during coast down / deceleration

to save fuel.

l

Intank fuel pump :

Self priming fuel system. No fuel vapour lock

under hot soak / summer conditions.

l

Knock sensor :

Knock sensor fitted on the block to sense the

engine knock and give the feed back to ECU

to adjust the ignition for smooth engine

operation (and to prevent engine damage in

case of poor quality of fuel used).

l

Fuel circuit inertia switch :

In case of Impact / accident the inertia switch

automatically cuts off fuel supply thus prevent

any fire hazard due to fuel spillage (The switch

can be reset by thumb press). The inertia

switch is located at LH 'A' pillar lower trim below

dashboard. Fig 2

INERTIA

SWITCH

486 PL EMS-ECU

Fig. 1

Fig. 2