HVAC

869

HVAC

COMPRESSOR SPECIFICATIONS

Compressor can be used under below conditions & ranges stated below.

Refrigerant

HFC – 134a

Compressor oil

ATMOS GU10 (110

±10

ml.) / Equivalant

Direction of rotation

Clockwise / when looked from clutch side

Regular rotation [r/min]

700 ~ 7200

Maximum rotation allowed [r/min]

8200 (Please add high-speed-cut control.)

Comp. Ambient temp. ºC at every usage range.

Below 100 ºC

Applied voltage to clutch [V]

10 ~ 15V If it becomes lower than 10V, clutch will not

engage.

Relief Valve Specifications

Opening Pressure Range 3.50 ~ 4.14 MPa

Minimum Reseal Pressure 3.00MPa

Explanation of Relief Valve

High pressure refrigerant gas and lubricant discharges

from relief valve, when abnormal pressure occurred

Rated Voltage

DC12V

Power Consumption

25.7W at 20ºC Saturation

Current Saturation Value

2.14A

To Prevent Damage of Bearing for rotors

Recommendation for Belt Tension : 600 ± 100 Nm

Anti slugging valve (Rear plate)

This compressor has anti slugging valve to prevent the

abnormal pressure of refrigerant by liquid compression.