Background Image
Table of Contents Table of Contents
Previous Page  1211 / 1575 Next Page
Information
Show Menu
Previous Page 1211 / 1575 Next Page
Page Background

STORME 400NM

SR

NO

DTC

FTB

DESCRIPTION

CAUSES

EFFECT ON VEHICLE

CHECK

POINTS

CORRECTIVE ACTION

MIL

STATUS

CEL

8

P0046

35

Signal high time >

maximum.

1. This fault gets logged if Incorrect

PWM signal is applied to VGT actuator

by EMS ECU.

EMS ECU takes following

recovery actions:

1.

Apply reduce torque 3 mode:(70%

of torque cut off at 2700erpm)

2.

Disable SPC strategy, no more

sPC trim update.

3.

VGT position control disabled and

recovery position applied.

4.

Disable the AMF sensor learning.

5.

Disable the AMF plausibility test.

6.

Disable cruise control function.

7.

Disable EGR control and close

EGR valve.

1.

Check 30A fuse connected to EMS power relay and battery

(+ve) power supply is not blown off. Replace if required.

2.

Check whether VGT actuator is stuck open/mechanical damage

to VGT actuator. In case of severe damage replace VGT

actuator.

3.

Check the continuity between the EMS ECU pin A89 to the

VGT actuator connector pin 4 && Main relay power supply to

Actuator connector pin 1 and rectify if any wiring harness

issues are found.

4.

Check whether the VGT actuator connector pin 2 is connected

to ground and Connector pins 3 & 5 are connected to CAN H

and CAN L lines.

5.

Check whether the VGT actuator control pin A89 is either short

circuited to ground/battery. If so the rectify the wiring harness

connections to make them inline with circuit schematics.

6.

Check ECU pins and connector, Replace if found defective.

7.

If still problem persists then replace VGT actuator with new

one.

8.

If problem still persists then replace EMS ECU.

ON

OFF

9

P0047

11

Circuit Short to Ground

This fault gets logged if the VGT

actuator drive pin of EMS ECU is short

circuited to ground.

ECU used to take following

recovery action if it found

turbocharger/supercharger

boost control "A" circuit issue:-

1.

Disable the AMF sensor learning.

2.

Disable the AMF plausibility test.

3.

Disable cruise control function.

4.

Disable EGR control and close

EGR valve~5. Apply reduce

torque 3 mode :( 70% of torque

cut off at 2700erpm).

5.

Disable SPC (Speed Pilot Control)

strategy, no more sPC trim

update.

6.

VGT position control disabled and

recovery position applied.

1.

Check 30A fuse connected to EMS power relay and battery

(+ve) power supply is not blown off. Replace if required.

2.

Check whether VGT actuator is stuck open/mechanical damage

to VGT actuator. In case of severe damage replace VGT

actuator.

3.

Check the continuity between the EMS ECU pin A89 to the

VGT actuator connector pin 4 && Main relay power supply to

Actuator connector pin 1 and rectify if any wiring harness

issues are found.

4.

Check whether the VGT actuator connector pin 2 is connected

to ground and Connector pins 3 & 5 are connected to CAN H

and CAN L lines.

5.

Check whether the VGT actuator control pin A89 is either short

circuited to ground. If so the rectify the wiring harness

connections to make them inline with circuit schematics.

6.

Check ECU pins and connector, Replace if found defective.

7.

If still problem persists then replace VGT actuator with new

one.

8.

If problem still persists then replace EMS ECU.

ON