K. SOLENOID VALVE REMOVAL 1. Discharge refrigerant from AC system by using standard recovery instruments. 2. Remove electrical connection on solenoid valve. 3. Loosen two nuts of solenoid valve and take out valve from pipe. 4. Remove solenoid valve mounting nut on Body. FITMENT Follow the reverse procedure of removal. L. AIR PURIFIER (IF APPLICABLE) CABIN AIR PURIFICATION I. The Climate Control System fitted with advance filter for cabin air purification. PM2.5 Combi filter (If available): This high • efficiency filter cleans the PM2.5 particles and harmful gases coming from atmosphere pollution and volatile organic compounds. AIR QUALITY INDEX: (IF AVAILABLE) II. Climate control system fitted with FATC • calculates Air Quality Index (AQI) of cabin using PM2.5 AQI Index. FATC System in AUTO Mode automatically sets • the blower speed and switches to recirculation air mode to improve AQI inside the cabin. The calculated AQI is displayed on display unit • along with severity index. NOTE Replace the Filter as per Maintenance schedule. If the vehicle is driven in heavy dusty conditions more frequent filter replacement are required. Replace the filter if you find poor ventilation, Cooling or Demisting. NOTE AQI calculation will be effective after 30 seconds after ignition ON and no value will be displayed during this period. If the AQI does not improve in some time, get the sensor and Cabin filter inspected. Vacuum the dust sensor as per the maintenance schedule. FATC 67