Q5/X451 FATC DTC Troubleshooting Data Version: 1.0 Date: 16-Oct-2018 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. Author: ERC Page: 60 of 202 B1F1F-15:- Air Temperature Feedback Signal - Circuit Short to Battery or Open; ISO Code B1F1F – 15 Customer Symptom System is less responsive to user control and environmental conditions Fault Effects (On Vehicle) 1) If Motor learning is in process, end stops will not be learnt properly 2) Motor will not be positioned accurately 3) Cooling and Heating will not be accurate Lamp Status (If Any) When Air Temperature feedback signal STS is detected, motor will stay at current position. Thereafter if any new user request comes/AUTO, motor will be driven on Time basis. Fault Detection Condition Temperature Door Control Motor Feedback Line - Circuit short to Battery or Open Normal Operating Condition With the Temperature feedback line connected to the harness and with Ignition ON, checks the voltage between blue connector pin no 10 & ground of the Connector. The voltage range should be in between 1.3 to 3.89 V Probable Trouble Area 1) Motor connector is not connected firmly (open) 2) Motor feedback line short to Battery 3) Motor feedback line open 4) Motor feedback ground line is open Healing Condition If there is a continuity between the Driver side temperature door actuator Feedback line and Battery line correct the wiring harness (wiring harness short to battery) Component Details: The actuator controls the position of the temperature blend door based on the voltage signal from the FATC module. Potentiometer, inside the actuator, sends a feedback signal to the controller and controller cuts off the voltage signal coming from the controller when the required door position is achieved. Preliminary Checks: Switch On the IGN & perform the following check. 1) Connect the Diagnostics tool & check the DTC fault code 2) Read ECU parameter value Target Position of Temperature Door Flap and Temperature Door flap Position (Internal Value) for actual and target position of Actuator
RkJQdWJsaXNoZXIy MTIwNTUz