Automated Manual Transmission 45  Hydraulic system fluids for gearbox with hydraulic selection – check level and top up if necessary. Connect the Battery connections and re- move the battery support / drip tray. Connect the diagnosis equipment and carry out the following operations:  Hydraulic system for gearbox with hy- draulic selection – Bleed air.  Clutch self-calibration enablement.  Grid self tuning - service.  New actuators (only if the hydraulic actu- ation unit is being replaced). Remove the car from the lift. Pressure Accumulator on Hydraulic Actuator Unit Removal: Connect the diagnosis equipment and carry out the accumulator depressurisation pro- cedure. Disconnect the battery and remove the battery and battery support / drip tray. 1. Unscrew and remove the pressure accu- mulator (1a) complete with O-ring (1b). Pressure Accumulator on Hydraulic Actuator Unit Fitment: 1. Place the pressure accumulator (1a) com- plete with new O-ring (1b) back in its housing and tighten it to the prescribed torque. Component Fixing Dia Value (Nm) Pressure accu- mulator 8 – 10 Refill the electro-hydraulic selection gear- box hydraulic control system, with reference to:  Hydraulic system fluids for gearbox with hydraulic selection – check level and top up if necessary. Connect the Battery connections and re- move the battery support / drip tray. Connect the diagnosis equipment and carry out the following operations:  Hydraulic system for gearbox with hy- draulic selection – Bleed air.  Clutch self-calibration enablement.  Grid self tuning - service.  New actuators (only if the hydraulic actu- ation unit is being replaced).