HEXA
ENGINE 186 11. Loosen and remove three mounting nuts and take out the turbocharger (1) from exhaust man- ifold (2). FITMENT For fitment follow the reverse procedure of removal. NOTE Use new gasket and sealing washer every time and tighten bolts to specified torque. Check that the sealing washers are fitted on the oil feeder line at the time of assembly. 16. EGR VALVE ACTUATOR A DC motor drive is used to move the EGR valve over the complete movement range. The DC motor is directly controlled by the ECU of the Diesel en- gine. EMS ECU High power integrated H-bridge EGR actuator driver has diagnostics and fault de- tection feature. This driver is used for bi directional current control of motor driven EGR actuator . LOCATION EGR cooler assembly is mounted above intake manifold . CONNECTOR DETAILS