HVAC 70 5. When rotor is hard to remove by hand, use mag- netic clutch puller to remove it.  Be sure to use magnetic clutch pulley remover. As there is a possibility that the push stick of the puller can damage the compressor shaft if directly mounted on it.  The push rod of the gear puller should not be turned too forcibly, or the rotor may be deformed. 6. Remove the wiring bracket fixing screw by using (Phillips screw driver (+)) (1), and disconnect the connector (2). 7. Remove the snap ring (1) of the field coil using snap ring pliers (2). WARNING Care should be taken while removing the snap ring by preventing it from jumping out; otherwise it may cause serious injuries. 8. Pry the field coil (1) with a flat-tip screwdriver, to remove it from the compressor body.