ELECTRICAL 246 F. DRIVER INFORMATION CENTER: SR. NO. PARAMETERS CHARACTERISTICS 1 Main Odometer Range: 0 to 999999 Resolution : 1 km The Odometer reading shall not over flow to “0” when the maximum value is accumulated; the display shall freeze to maximum value. 2 Trip meter (A & B) Range: 0.0 to 9999.9 (5 digits, Leading zero’s shall be suppressed) Resolution: 0.1 km Trip meter reading shall over flow to “0.0” after it crosses 9999.9 kms. Trip meter reset : Trip meter (A & B) shall be reset by pressing “Trip” switch for more than 1.5 secs. When the particular Trip-meter is selected DIC switch should be in “Trip” mode. 3 Fuel Computer - Instantaneous Fuel Consumption Range: 0.0 to 99.9 (3 digits, Leading zero’s shall be suppressed) Resolution: 0.1 km/l or L/100km 4 Fuel Computer - Average Fuel Consumption (A & B) Range: 0.0 to 99.9 (3 digits, Leading zero’s shall be suppressed) Resolution: 0.1 km/l or L/100km 5 Fuel Computer - Range (Distance to Empty) Range: 0 to 999 (3 digits, Leading zero’s shall be suppressed) Resolution: 1 km 999999 km INST FUEL 99.9 km/l INST FUEL 99.9 L/100km A: 9999.9 km B: 9999.9 km RANGE 999 km AVG FUEL A 99.9 km/l AVG FUEL A 99.9 L/100km AVG FUEL B 99.9 km/l AVG FUEL B 99.9 L/100km