HEXA

ELECTRICAL 48 REFITMENT: 1.Match the dowel with corresponding hole on the clutch housing. 2.Fit the three mounting bolts and tight with specified torque and sequence/order. ( Refer above given fitment detail figure for tightening torque) 3.Connect the electrical connection of the starter motor. ! CAUTION: Tighten all the mounting bolts of starter motor in given order with desired torque. Do not exceed torque value, it will result in damage. STARTER SOLENOID TEST 1. Disconnect the field coil wire from the M- terminal of solenoid switch. 2. Connect a 12V battery between S-terminal and the starter body. 3. Connect the field coil wire to the M-terminal. CAUTION This test must be performed quickly (in less than 10 seconds) to prevent the coil from burning. 4. If the pinion moves out, the pull-in coil of solenoid is working properly. If the pinion does not move, replace the solenoid. 5. Disconnect the field coil wire from the M- terminal. 6. If the pinion has moved out, the hold-in coil of the solenoid is working properly. If the pinion moves in, replace the solenoid.