HVAC

20

Feedback Signal Values for Temperature Actuator

Detent Position

Knob Angle in

Degrees (CW

starting from the

initial position)

Voltage

Min (V)

Nominal (V)

Max (V)

0

0

0.65

0.70

0.75

1

9

0.76

0.81

0.86

2

18

0.88

0.93

0.98

3

27

0.99

1.04

1.09

4

36

1.11

1.16

1.21

5

45

1.22

1.27

1.32

6

54

1.34

1.39

1.44

7

63

1.45

1.50

1.55

8

72

1.56

1.61

1.66

9

81

1.68

1.73

1.78

10

90

1.79

1.84

1.89

11

99

1.91

1.96

2.01

12

108

2.02

2.07

2.12

13

117

2.14

2.19

2.24

14

126

2.25

2.30

2.35

15

135

2.37

2.42

2.47

16

144

2.48

2.53

2.58

17

153

2.59

2.64

2.69

18

162

2.71

2.76

2.81

19

171

2.82

2.87

2.92

20

180

2.94

2.99

3.04

21

189

3.05

3.10

3.15

22

198

3.17

3.22

3.27

23

207

3.28

3.33

3.38

24

216

3.39

3.44

3.49

25

225

3.51

3.56

3.61

26

234

3.62

3.67

3.72

27

243

3.74

3.79

3.84

28

252

3.85

3.90

3.95

29

261

3.97

4.02

4.07

30

270

4.08

4.13

4.18